Key words: H2S concentration, H2S fluid analyzer, gas detector tube, preliminary water discharge unit, multi-zone field, associated petroleum gas, annulus, dynamic head.
The exploitation efficiency of oil fields with H2S concentrations depends on the monitoring quality all the way from the bottom-hole to the stock-tank oil delivery and associated petroleum gas sales points. Numerous studies show that without certain physical and (or) chemical treatment, the concentration of H2S in the produced water, oil and associated gas remains constant for a long time. This permanence makes it possible to solve a number of field development tasks such as mapping reservoir flooding patterns, separating oil production from multi-zone field with numerous targets, indirect assessment of corrosion on field equipment.
References
1. ST-04-03-01/OOO, Primenenie neytralizatorov serovodoroda na ob"ektakh ANK “Bashneft'” (The use of hydrogen sulfide converters on the fields of "Bashneft"), Ufa: Publ. of “Bashneft'-Dobycha”, 2010, 21 p.
2. Patent no. 2286453 S2 RF, Sposob otsenki gidrodinamicheskoy svyazi mezhdu skvazhinami serovodorodsoderzhashchego mestorozhdeniya (Method to estimate hydrodynamic connection between wells drilled in hydrogen sulfide containing deposit), authors: Denislamov I.Z., Shaydullin F.D., Sitdikov I.F., Aminov A.F.
3. Valeev M.D., Belousov Yu.V, Kalugin A.V., Neftyanoe khozyaystvo – Oil Industry, 2005, no. 3, pp. 108-109.